GI LPG REDUCER R-UNO

R-UNO LPG REDUCER

 

Entry pipe fitting: Fitting for copper pipe carrying LPG from tank

Added heating stage: The LPG is heated in order to obtain better engine performances

LPG Filter: Component used to clean the LPG coming from tank

Solenoid valve: Normally closed, has the function to intercept and stop the LPG flow when

the engine is not running or powered by petrol.

Reducer 1° stage: Chamber that allow a reduction of pressure of the LPG

Outlet fitting: Fitting for copper pipe at the outlet of the reducer, to the engine.

Outlet pressure: Allows a manual regulation of the outlet pressure in order to meet the

requirement of the different automotive engines

Pressure relief valve: Valve with a retaining spring that allows the relief of the LPG in vapour

phase from the reducer, in case of overpressure.

 

TECHNICAL DATA 

Material: Die cast aluminium body, CNC machined

Weight: 0,760kg (without accessories)

Size: L - 156mm H - 74mm B - 92mm

Max. inlet pressure: 3 MPa

Outlet pressure: Variable from 80 to 180 KPa (when tested non connected to the engine)

Solenoid voltage: 13,8 V dc (12V) *

* When engine working

Solenoid power dissipation: 12 V (11W)

All other functional and environmental characteristic:

According to Regulation ECE 67R - 01

Engine Power: Suitable for small to medium power engines (150 HP) operating at ambient temperature not lower than -10° C.

For the regions with colder climate (up to -30oC) the power have to be decreased with 20%.

In case of operation at temperatures permanently higher than the indicated limit, the LPG reducer can be used on engines having power exceeding the range above indicated (+10%). 

 